PERBEDAAN HASIL PEMERIKSAAN LED SECARA MANUAL DAN MENGGUNAKAN ALAT AUTOMATIC

Wahyudi, Arip (2023) PERBEDAAN HASIL PEMERIKSAAN LED SECARA MANUAL DAN MENGGUNAKAN ALAT AUTOMATIC. Undergraduate thesis, Universitas Katolik Musi Charitas.

[img] Text (Cover)
TLM-2023-1934022-Cover.pdf

Download (610kB)
[img] Text (Abstrack)
TLM-2023-1934022-Abstract.pdf
Restricted to Registered users only

Download (230kB) | Request a copy
[img] Text (Table of Content)
TLM-2023-1934022-Table of Content.pdf
Restricted to Registered users only

Download (259kB) | Request a copy
[img] Text (Chapter 1)
TLM-2023-1934022-Chapter 1.pdf
Restricted to Registered users only

Download (388kB) | Request a copy
[img] Text (Chapter 2)
TLM-2023-1934022-Chapter 2.pdf
Restricted to Registered users only

Download (832kB) | Request a copy
[img] Text (Chapter 3)
TLM-2023-1934022-Chapter 3.pdf
Restricted to Registered users only

Download (804kB) | Request a copy
[img] Text (Chapter 4)
TLM-2023-1934022-Chapter 4.pdf
Restricted to Registered users only

Download (417kB) | Request a copy
[img] Text (Conclusion)
TLM-2023-1934022-Conclusion.pdf
Restricted to Registered users only

Download (223kB) | Request a copy
[img] Text (Bibliography)
TLM-2023-1934022-Bibliography.pdf
Restricted to Registered users only

Download (329kB) | Request a copy
[img] Text (Attachment)
TLM-2023-1934022-Attachment.pdf
Restricted to Registered users only

Download (2MB) | Request a copy
[img] Text (Complete)
TLM-2023-1934022-Complete.pdf
Restricted to Repository staff only

Download (3MB) | Request a copy
[img] Text (Summary_ID)
TLM-2023-1934022-Summary_Id.pdf
Restricted to Registered users only

Download (466kB) | Request a copy

Abstract

Background: In 1973 it was stated and published that the Westergren method was the method recommended by the ICSH (International Committee for Standardization in Hematology). The manual LED examination of the Westergren method was carried out on blood samples with EDTA anticoagulant and took 60 minutes, but now an LED examination with One of the automatic methods is using the HumaSRate tool. The HumaSRate tool only takes 20 minutes to examine samples. In this study the researchers examined the differences in LED inspection results manually and using automatic tools. The results of this study found that there were no differences in LED inspection results between methods manual and automatic. Objective : Know the differences in LED Inspection Results Manually and Using Automatic Tools Methods : This research is an analytic observation with a cross sectional approach using total sampling technique. The research subjects were 33 students who met the inclusion and exclusion criteria. The results of LED inspection using manual and automatic methods were tested using the Wilcoxon test. Results : The average manual method of LED inspection is 18.5 mm/hour. The average LED inspection by the automatic method is 19.0 mm/hour with a statistical test result of p-value = 0.167 (> 0.05). Conclusion : There is no difference in the results of the LED inspection between the manual and automatic methods.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: LED, Westergren, LED automatic method.
Subjects: R Medicine > R Medicine (General)
R Medicine > RZ Other systems of medicine
Divisions: Undergraduate Theses - D3/D4 > Medical Laboratory Technology Diploma Study Program
Depositing User: wahyudi Arip
Date Deposited: 04 Oct 2023 01:35
Last Modified: 04 Oct 2023 01:35
URI: http://eprints.ukmc.ac.id/id/eprint/10991

Actions (login required)

View Item View Item