.,, Suryani (2019) Perbedaan Kadar Alanine Aminotransferase (Alt) Dalam Serum Dari Darah Yang Disentrifugasi Pada Kecepatan 3000 Rpm Selama 5 Menit Dan 4400 Rpm Selama 3 Menit. Undergraduate thesis, Universitas Katolik Musi Charitas.
Text
TLM-2019-1534047-cover.pdf Download (394kB) |
|
Text
TLM-2019-1534047-abstract.pdf Download (68kB) |
|
Text
TLM-2019-1534047-tableofcontent.pdf Download (75kB) |
|
Text
TLM-2019-1534047-chapter1.pdf Download (93kB) |
|
Text
TLM-2019-1534047-chapter2.pdf Restricted to Repository staff only Download (293kB) |
|
Text
TLM-2019-1534047-chapter3.pdf Restricted to Repository staff only Download (161kB) |
|
Text
TLM-2019-1534047-chapter4.pdf Restricted to Repository staff only Download (141kB) |
|
Text
TLM-2019-1534047-conclusion.pdf Download (24kB) |
|
Text
TLM-2019-1534047-reference.pdf Download (91kB) |
|
Text
TLM-2019-1534047-attachment.pdf Restricted to Repository staff only Download (934kB) |
|
Text
TLM-2019-1534047-complete.pdf Restricted to Repository staff only Download (1MB) |
Abstract
Background : Laboratory tests for liver and heart are emergency, so the examination must be carried out quickly including ALT examination. One way is by reducing the time of centrifugation without reducing the quality of serum. Reducing the time of centrifugation to 3 minutes at 4400 rpm is expected to provide the same results by centrifuging for 5 minutes at 3000 rpm. So that, the duration of ALT examination can be faster, reduces Turnaround Time (TAT) or patient waiting time, and saves electrical energy which can reduce the variable cost. Method : This research was a pre-experimental study with Static Group Comparison research design. The examination used IFCC without pyridoxal method. The subjects of research were 22 people. Samples were serum of blood that were frozen for 30 minutes then centrifuged at 3000 rpm for 5 minutes and 4400 rpm for 3 minutes. Samples were examined using A15 biosystem instrument. Data were analyzed by Wilcoxon test. Result : The results showed mean value of ALT centrifuged at 3000 rpm for 5 minutes was 16,32 U/L and 4400 rpm for 3 minutes was 16,50 U/L. Based on Wilcoxon test, there was no difference in ALT level from centrifuged blood samples at 3000 rpm for 5 minutes and 4400 rpm for 3 minutes, p-value (sig) = 0.676 with a significant level (α = 0.05) then p-value (sig. 2 tailed) > 0.025. Conclusion : There was no difference in ALT level in serum from blood that was centrifuged at 3000 rpm for 5 minutes and 4400 rpm for 3 minutes.
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | Skripsi lengkap dapat dibaca di Ruang Referensi Perpustakaan UKMC Kampus Burlian |
Uncontrolled Keywords: | Keywords : ALT, centrifugation, time |
Subjects: | Q Science > QD Chemistry T Technology > TP Chemical technology |
Divisions: | Undergraduate Theses - D3/D4 > Medical Laboratory Technology Diploma Study Program |
Depositing User: | Perpustakaan Unika Musi Charitas |
Date Deposited: | 16 May 2020 04:48 |
Last Modified: | 16 May 2020 04:48 |
URI: | http://eprints.ukmc.ac.id/id/eprint/3634 |