Wulandari, Reni (2026) Perbedaan Derajat Aglutinasi Pada Sampel Suspensi Golongan Darah 5% Metode Tabung Pada Variasi Volume Antisera. Diploma thesis, Universitas Katolik Musi Charitas.
TLM-2026-2234007-cover.pdf
Download (434kB)
TLM-2026-2234007-abstract.pdf
Restricted to Registered users only
Download (74kB) | Request a copy
TLM-2026-2234007-table of content.pdf
Restricted to Registered users only
Download (96kB) | Request a copy
TLM-2026-2234007-chapter 1.pdf
Restricted to Registered users only
Download (148kB) | Request a copy
TLM-2026-2234007-chapter 2.pdf
Restricted to Registered users only
Download (423kB) | Request a copy
TLM-2026-2234007-chapter 3.pdf
Restricted to Registered users only
Download (338kB) | Request a copy
TLM-2026-2234007-chapter 4.pdf
Restricted to Registered users only
Download (326kB) | Request a copy
TLM-2026-2234007-conclusion.pdf
Restricted to Registered users only
Download (106kB) | Request a copy
TLM-2026-2234007-bibliography.pdf
Restricted to Registered users only
Download (158kB) | Request a copy
TLM-2026-2234007-attachment.pdf
Restricted to Registered users only
Download (510kB) | Request a copy
TLM-2026-2234007-complete.pdf
Restricted to Repository staff only
Download (3MB) | Request a copy
TLM-2026-2234007-Summary_id.pdf
Restricted to Registered users only
Download (350kB) | Request a copy
Abstract
Background: Blood group testing using the tube method is the gold standard for ensuring the accuracy of blood transfusions. Variations in antiserum volume are thought to influence the degree of agglutination; however, there is currently no evidence regarding the most efficient antiserum volume capable of producing an optimal degree of agglutination in a 5% erythrocyte suspension.
Objective: To determine differences in the degree of agglutination during blood group testing on 5% blood group suspension samples using the tube method
Methods: This study was an analytical observational study with a cross-sectional design. The study subjects were 34 students from the Diploma IV Programme in Medical Laboratory Technology. Data were analysed using the Kruskal-Wallis test and Dunn’s post-hoc test
Results: From the 34 samples with three different treatments, the results showed that testing using antiserum volumes of 1, 2 and 3 drops in a 5% erythrocyte suspension sample using the tube method yielded an average agglutination degree of 4 positive (4+)
Conclusion: There was no difference in the degree of agglutination in blood group testing using a 5% erythrocyte suspension with the tube method and antiserum volumes of 1, 2 and 3 drops, with a p-value of 1.000 > 0.05.
Recommendation: The use of a 1-drop (50 µl) volume of antiserum is sufficient to produce a clear degree of agglutination in tube-based blood group testing using a 5% erythrocyte suspension, thereby potentially improving reagent efficiency, saving time and producing accurate results.
Keywords: Volume variation antiserum, degree of agglutination.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Volume variation antiserum, degree of agglutination. |
| Subjects: | R Medicine > RA Public aspects of medicine R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine R Medicine > RB Pathology R Medicine > RC Internal medicine |
| Divisions: | Undergraduate Theses - D3/D4 > Medical Laboratory Technology Diploma Study Program |
| Depositing User: | Wulandari Reni |
| Date Deposited: | 02 Sep 2026 07:36 |
| Last Modified: | 02 Sep 2026 07:36 |
| URI: | https://eprints.ukmc.ac.id/id/eprint/16669 |
