perbedaan kadar ureum pada serum yang segera diperiksa setelah sentrifugasi dan ditunda 3 jam pada suhu ruang

Febriyanti, Anastasya Fera (2022) perbedaan kadar ureum pada serum yang segera diperiksa setelah sentrifugasi dan ditunda 3 jam pada suhu ruang. Diploma thesis, Universitas Katolik Musi Charitas.

[img] Text (cover)
TLM-2022-1834002-Cover.pdf

Download (833kB)
[img] Text (abstract)
TLM-2022-1834002-Abstract.pdf
Restricted to Registered users only

Download (163kB) | Request a copy
[img] Text (tableofcontent)
TLM-2022-1834002-Tableofcontent.pdf
Restricted to Registered users only

Download (225kB) | Request a copy
[img] Text (chapter 1)
TLM-2022-1834002-Chapter 1.pdf
Restricted to Registered users only

Download (230kB) | Request a copy
[img] Text (chapter 2)
TLM-2022-1834002-Chapter 2.pdf
Restricted to Registered users only

Download (873kB) | Request a copy
[img] Text (chapter 3)
TLM-2022-1834002-Chapter 3.pdf
Restricted to Registered users only

Download (575kB) | Request a copy
[img] Text (chapter 4)
TLM-2022-1834002-Chapter 4.pdf
Restricted to Registered users only

Download (391kB) | Request a copy
[img] Text (conclusion)
TLM-2022-1834002-Conclusion.pdf
Restricted to Registered users only

Download (261kB) | Request a copy
[img] Text (Bibliography)
TLM-2022-1834002-Bibliography.pdf
Restricted to Registered users only

Download (212kB) | Request a copy
[img] Text (attachment)
TLM-2022-1834002-Attachment.pdf
Restricted to Registered users only

Download (5MB) | Request a copy
[img] Text (complete)
TLM-2022-1834002-Complete.pdf
Restricted to Repository staff only

Download (7MB) | Request a copy
[img] Text (summary_id)
TLM-2022-1834002-Summry_id.pdf
Restricted to Registered users only

Download (399kB) | Request a copy

Abstract

Background: one of the clinical chemistry tests is the level of urea. One of the factors that influence the examination of urea levels is a delay. Delaying the examination of urea levels that are not in accordance with the procedure can interfere with the composition, structure, and enzymes contained in the serum. Objective: to determine the difference in serum urea levels which were immediately examined after centrifugation and delayed for 3 hours at room temperature. Methods: This type of research is analytic observational with a static group comparison design. The research subjects used were 31 medical laboratory technology students. The research subjects were collected and collected blood in 1 clot activator tube, the collected blood was centrifuged, then the serum obtained was examined by treating serum samples which were immediately examined and delayed for 3 hours at room temperature. Result: The results showed that the mean serum urea level which was immediately examined was 20.99 mg/dl and in serum that was delayed for 3 hours, it was 17.55 mg/dl. These data were analyzed and showed no difference in serum urea levels which were examined immediately after centrifugation and delayed for 3 hours at room temperature. Conclusion: Based on the results of the study, there was a difference in serum urea levels which were immediately examined after centrifugation and delayed for 3 hours at room temperature. Suggestion: urea levels can be checked by checking immediately. For storage, the temperature can be done at room temperature.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: urea level, delay, room temperature
Subjects: R Medicine > RZ Other systems of medicine
Divisions: Undergraduate Theses - D3/D4 > Medical Laboratory Technology Diploma Study Program
Depositing User: Anastasya fera febriyanti
Date Deposited: 13 Sep 2022 08:18
Last Modified: 13 Sep 2022 08:18
URI: http://eprints.ukmc.ac.id/id/eprint/9006