Herdiyanto, Gusti (2021) PERBEDAAN KADAR ASPARTATE AMINOTRANSFERASE (AST) DALAM SERUM DARAH YANG DISENTRIFUGASI 3000 RPM SELAMA 5 MENIT DAN 5000 RPM SELAMA 1 MENIT. Diploma thesis, Universitas Katolik Musi Charitas.
Text (Cover)
TLM-2021-1734010-cover.pdf Download (1MB) |
|
Text (Abstract)
TLM-2021-1734010-abstract.pdf Restricted to Registered users only Download (120kB) | Request a copy |
|
Text (Table of content)
TLM-2021-1734010-tableofcontent.pdf Restricted to Registered users only Download (190kB) | Request a copy |
|
Text (chapter 1)
TLM-2021-1734010-chapter 1.pdf Restricted to Registered users only Download (136kB) | Request a copy |
|
Text (chapter 2)
TLM-2021-1734010-chapter 2.pdf Restricted to Registered users only Download (535kB) | Request a copy |
|
Text (chapter 3)
TLM-2021-1734010-chapter 3.pdf Restricted to Registered users only Download (415kB) | Request a copy |
|
Text (chapter 4)
TLM-2021-1734010-chapter 4.pdf Restricted to Registered users only Download (223kB) | Request a copy |
|
Text (conclusion)
TLM-2021-1734010-conclusion.pdf Restricted to Registered users only Download (118kB) | Request a copy |
|
Text (bibliography)
TLM-2021-1734008-bibliography.pdf Restricted to Registered users only Download (178kB) | Request a copy |
|
Text (attachment)
TLM-2021-1734010-attachment.pdf Restricted to Registered users only Download (3MB) | Request a copy |
|
Text (complete)
TLM-2021-1734010-complete.pdf Restricted to Repository staff only Download (5MB) | Request a copy |
|
Text (summary_id)
TLM-2021-1734010-summary_id.pdf Restricted to Registered users only Download (374kB) | Request a copy |
Abstract
Aspartate Aminotransferase (AST) is an intracellular enzyme that is very important for the body, so the result of the examination must be released quickly. One that can be done is to shorten the time and increase the speed od centrifugation. This research conducted centrifugation at 5000 rpm for 1 minute. Examination using sample in the form of serum. Objective : To determine the diffrence in serum AST levels from blood centrifuged at 3000 rpm for minute and 5000 rpm for 1 minute. Methods : This type of research is Pre-experimental with a static group comparison research design. The subjects of this study were 32 respondents who had met the inclusion and exclusion criteria. The blood samples were then frozen at room temperature for 20 – 30 minute, then centrifuged at 3000 rpm for 5 minute and 5000 rpm for 1 minute. The examination method used is the IFCC method without pyridoxal. The data were analyzed using Wilcoxon Signed Rank Test statistical test. Result : Aspartate Aminotransferase (AST) levels in blood serum that were still within norma limits. The normality test shows that the data is normally distributed, so to test the hypothesis using a Paired T test. The result of the there is no significant difference in serum from blood centrifuged at 3000 rpm for 5 minute and 5000 rpm for 1 minute wiht a pvalue (Sig2-tailed) 0f 0,262 > 0,05. Conclusion : Based on the resultsof this study, it can be conclude that there is no diffrence in the level of Aspartate Aminotransferase (AST) in serum from blood centrifuged at 3000 rpm for 5 minute and 5000 rpm for 1 minute. Suggestion : Applicatively the management of examination material, namely the centrifugation speed of 5000 rpm for 1 minute, can be an alternative of consideration in the AST examination.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Aspartate Aminotransferase (AST), Speed and Centrifugation |
Subjects: | R Medicine > RZ Other systems of medicine |
Divisions: | Undergraduate Theses - D3/D4 > Medical Laboratory Technology Diploma Study Program |
Depositing User: | Gusti Herdiyanto |
Date Deposited: | 09 Sep 2021 06:23 |
Last Modified: | 09 Sep 2021 06:23 |
URI: | http://eprints.ukmc.ac.id/id/eprint/6605 |
Actions (login required)
View Item |