PERBEDAAN KADAR GLUKOSA SEWAKTU DENGAN CHEMESTRY ANALYZER PADA SERUM YANG DISENTRIFUGASI DAN TIDAK DISENTRIFUGASI

Pranata, I Wayan Deni (2024) PERBEDAAN KADAR GLUKOSA SEWAKTU DENGAN CHEMESTRY ANALYZER PADA SERUM YANG DISENTRIFUGASI DAN TIDAK DISENTRIFUGASI. Diploma thesis, Universitas Katolik Musi Charitas.

[img] Text (Cover)
TLM-2024-2034010-Cover.pdf

Download (292kB)
[img] Text (Abstract)
TLM-2024-2034010-Abstract.pdf
Restricted to Registered users only

Download (41kB) | Request a copy
[img] Text (TableOfContent)
TLM-2024-2034010-TableOfContent.pdf
Restricted to Registered users only

Download (99kB) | Request a copy
[img] Text (Chapter 1)
TLM-2024-2034010-Chapter 1.pdf
Restricted to Registered users only

Download (141kB) | Request a copy
[img] Text (Chapter 2)
TLM-2024-2034010-Chapter 2.pdf
Restricted to Registered users only

Download (529kB) | Request a copy
[img] Text (Chapter 3)
TLM-2024-2034010-Chapter 3.pdf
Restricted to Registered users only

Download (338kB) | Request a copy
[img] Text (Chapter 4)
TLM-2024-2034010-Chapter 4.pdf
Restricted to Registered users only

Download (247kB) | Request a copy
[img] Text (Conclusion)
TLM-2024-2034010-Conclusion.pdf
Restricted to Registered users only

Download (89kB) | Request a copy
[img] Text (Bibliography)
TLM-2024-2034010-Bibliography.pdf
Restricted to Registered users only

Download (123kB) | Request a copy
[img] Text (Attachment)
TLM-2024-2034010-Attachment.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text (Complete)
TLM-2024-2034010-Complete.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy
[img] Text (Summary_id)
TLM-2024-2034010-Summary_id.pdf
Restricted to Registered users only

Download (131kB) | Request a copy

Abstract

Background : Diabetes mellitus (DM) is a serious condition that lasts for a long time and causes an increase in blood glucose levels due to the body's inability to produce adequate amounts of the insulin hormone or to use the insulin produced effectively. Glucose tests in the laboratory based on the time of blood collection consist of random glucose, fasting glucose and 2 hour postprandial glucose. When checking blood glucose, serum can be obtained in two ways, namely centrifugation and not centrifugation (sedimentation). The serum obtained was centrifuged, the blood in the tube was frozen for 15 minutes then centrifuged, while the serum that was not centrifuged was left for 90 minutes. Objectiv : To determine the difference in glucose levels between centrifuged and uncentrifuged serum. Methods : This research uses observational analytics using a cross sectional approach. Observational is research where there is no treatment of one of the independent and dependent variables, and cross sectional is a research design by taking measurements at the same time between the independent and dependent variables. Result : The average glucose level in centrifuged serum was 81.36 mg/dL. The average glucose level in uncentrifuged serum was 82.36 mg/dL. Conclusion : There was no difference in the results of checking glucose levels using a chemistry analyzer in centrifuged and uncentrifuged serum with a value (2-tailed sig) of 0.678 > 0.05. Suggestion : For temporary glucose testing, it is not recommended to use serum that has not been centrifuged because the resulting glucose level is falsely low.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Glucose During GOD-PAP method, Centrifugation, Not Centrifugation.
Subjects: R Medicine > R Medicine (General)
R Medicine > RB Pathology
Divisions: Undergraduate Theses - D3/D4 > Medical Laboratory Technology Diploma Study Program
Depositing User: Pranata I Wayan Deni
Date Deposited: 30 Aug 2024 03:38
Last Modified: 30 Aug 2024 03:38
URI: http://eprints.ukmc.ac.id/id/eprint/12799