Andini, Veronica Else Dwi (2024) PERBEDAAN KADAR GLUKOSA DARAH SEWAKTU SPESIMEN YANG DI TAMPUNG PADA TABUNG VACUTAINER NON ADDITIVE SINY DAN BECTON DICKINSON (BD). Undergraduate thesis, Universitas Katolik Musi Charitas.
Text (cover)
1. TLM-2024-2034004p-Cover.pdf Download (1MB) |
|
Text (Abstract)
2. TLM-2024-2034004p-Abstract.pdf Restricted to Registered users only Download (37kB) | Request a copy |
|
Text (Table of content)
3. TLM-2024-2034004p-Table of Content.pdf Restricted to Registered users only Download (576kB) | Request a copy |
|
Text (Chapter 1)
4. TLM-2024-2034004p-Chapter 1.pdf Restricted to Registered users only Download (444kB) | Request a copy |
|
Text (Chapter 2)
5. TLM-2024-2034004p-Chapter 2.pdf Restricted to Registered users only Download (1MB) | Request a copy |
|
Text (Chapter 3)
6. TLM-2024-2034004p-Chapter 3.pdf Restricted to Registered users only Download (365kB) | Request a copy |
|
Text (Chapter 4)
7. TLM-2024-2034004p-Chapter 4.pdf Restricted to Registered users only Download (470kB) | Request a copy |
|
Text (Conclusion)
8. TLM-2024-2034004p-Conclusion.pdf Restricted to Registered users only Download (24kB) | Request a copy |
|
Text (Bibliography)
9. TLM-2024-2034004p-Bibliography.pdf Restricted to Registered users only Download (271kB) | Request a copy |
|
Text (Attachment)
10. TLM-2024-2034004p-Attachment.pdf Restricted to Registered users only Download (4MB) | Request a copy |
|
Text (Complete)
11. TLM-2024-2034004p-Complete.pdf Restricted to Repository staff only Download (9MB) | Request a copy |
|
Text (Summary_id)
12. TLM-2024-2034004p-Summary_id.pdf Restricted to Registered users only Download (887kB) | Request a copy |
Abstract
Background: Glucose is the main source of energy for the body. Glucose tests measure blood sugar levels. In this examination, the type of sample used is serum. Serum samples are obtained from blood in centrifuged non additive vacutainer tubes. Evaluation of various tube manufacturers is necessary to ensure reliability of results, especially if choosing cheaper tubes can increase profit margins. Tubes used were Siny and BD non additive vacutainer. Objective: To determine the blood glucose level of specimens collected in Siny and BD non additive vacutainer tubes. Methods: This study included quantitative research with the type of observational analytic research approach cross-sectional study. The research subjects were students who met the inclusion and exclusion criteria totaling 43 subjects. Blood samples were collected into Siny and BD non additive vacutainer tubes as much as 3 mL then centrifuged to obtain serum and examined with Kenza 450 TX equipment. Statistical hypothesis testing using Wilcoxon test with 95% confidence level. Results: The average value of glucose levels during specimens collected on Siny tubes was 85.75 mg/dL and the average glucose levels during specimens collected on BD tubes was 86.66 mg/dL. With Wilcoxon signed rank test obtained p-value = 0.484 (p> 0.05) Conclusion: There is no difference in glucose levels during specimens accommodated in Siny and BD non additive vacutainer tubes.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Glucose, Non Additive Vacutainer, Siny, BD. |
Subjects: | R Medicine > RZ Other systems of medicine |
Divisions: | Undergraduate Theses - D3/D4 > Medical Laboratory Technology Diploma Study Program |
Depositing User: | Andini Veronica Else Dwi |
Date Deposited: | 06 Aug 2024 08:23 |
Last Modified: | 06 Aug 2024 08:23 |
URI: | http://eprints.ukmc.ac.id/id/eprint/12578 |