Perbedaan Jumlah Leukosit Darah Vena Dengan Pembendungan 50 Detik Dan 80 Detik

Purba, Lamtiur A.L (2023) Perbedaan Jumlah Leukosit Darah Vena Dengan Pembendungan 50 Detik Dan 80 Detik. Undergraduate thesis, Universitas Katolik Musi Charitas.

[img] Text (cover)
TLM-2023-1934017-Cover.pdf

Download (243kB)
[img] Text (abstract)
TLM-2023-1934017-Abstract.pdf

Download (133kB)
[img] Text (tableofcontent)
TLM-2023-1934017-tableofcontent.pdf
Restricted to Registered users only

Download (86kB) | Request a copy
[img] Text (chapter 1)
TLM-2023-1934017-Chapter 1.pdf
Restricted to Registered users only

Download (179kB) | Request a copy
[img] Text (chapter 2)
TLM-2023-1934017-Chapter 2.pdf
Restricted to Registered users only

Download (591kB) | Request a copy
[img] Text (chapter 3)
TLM-2023-1934017-Chapter 3.pdf
Restricted to Registered users only

Download (253kB) | Request a copy
[img] Text (chapter 4)
TLM-2023-1934017-Chapter 4.pdf
Restricted to Registered users only

Download (196kB) | Request a copy
[img] Text (conclusion)
TLM-2023-1934017-Conclusion.pdf
Restricted to Registered users only

Download (71kB) | Request a copy
[img] Text (bibliography)
TLM-2023-1934017-Bibliography.pdf
Restricted to Registered users only

Download (143kB) | Request a copy
[img] Text (attachment)
TLM-2023-1934017-Attachment.pdf
Restricted to Registered users only

Download (2MB) | Request a copy
[img] Text (complete)
TLM-2023-1934017-Complete.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy
[img] Text (summary_id)
TLM-2023-1934017-Summary_id.pdf
Restricted to Registered users only

Download (290kB) | Request a copy

Abstract

Background: the pre-analytical stage is one of the stages in sample examination. Tourniquet blocking is one of the pre-analytical stages that can affect the results of the leukocyte count examination. According to CLSI, the tourniquet should not be held for more than 1 minute. In the laboratory, it often takes too long to apply a tourniquet which is caused by several factors. In this study, researchers conducted research on differences in the number of leukocytes in venous blood with 50 seconds and 80 seconds of damming. The results of this study concluded that there was no difference in the number of leukocytes with 50 second and 80 second containment. Purpose: Knowing the difference in the results of venous blood leukocyte counts with damming for 50 seconds and 80 seconds Methods: This research is an analytic observational study with a cross-sectional approach using a total sampling technique. There were 32 subjects in this study who met the inclusion and exclusion criteria. Venous blood was dammed using a tourniquet for 50 seconds and 80 seconds, then collected in a K2EDTA tube, then the number of leukocytes was checked using a Hematology tool – Sysmex XP-100 Analyzer. Data from the measurement of the number of leukocytes obtained were then tested using the Paired Sample T-test. Results: The average leukocyte count with 50 second containment was 7.34 x 103/µL and the average leukocyte count with 80 second containment was 7.30 x 103/µL. Conclusion: There is no difference in the results of examination of the leukocyte count of venous blood with damming for 50 seconds and 80 seconds with a value (sig 2 tailed) 0.211> 0.05. Suggestion: 80 second dam can still be used because it does not affect the results of the leukocyte examination

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Leukocytes, Dam, Venous blood
Subjects: R Medicine > R Medicine (General)
R Medicine > RZ Other systems of medicine
Divisions: Undergraduate Theses - D3/D4 > Medical Laboratory Technology Diploma Study Program
Depositing User: Purba Lamtiur A.L
Date Deposited: 23 Aug 2023 03:59
Last Modified: 23 Aug 2023 03:59
URI: http://eprints.ukmc.ac.id/id/eprint/10608

Actions (login required)

View Item View Item